Structural parameters optimization of louver fins of air⁃cooled charge air cooler
|更新时间:2025-05-26
|
Structural parameters optimization of louver fins of air⁃cooled charge air cooler
“In the field of air-cooled intercoolers, experts have established a complete second-order regression model for heat transfer characteristics and flow resistance characteristics through a three factor five level experimental design. Response surface methodology and multi-objective genetic algorithm are used for optimization calculation, providing a solution for optimization design.”
Journal of Jilin University(Engineering and Technology Edition)Vol. 53, Issue 4, Pages: 998-1006(2023)
LI Sheng,ZHU Jia,HUANG De-hui,et al.Structural parameters optimization of louver fins of air⁃cooled charge air cooler[J].Journal of Jilin University(Engineering and Technology Edition),2023,53(04):998-1006.
LI Sheng,ZHU Jia,HUANG De-hui,et al.Structural parameters optimization of louver fins of air⁃cooled charge air cooler[J].Journal of Jilin University(Engineering and Technology Edition),2023,53(04):998-1006. DOI: 10.13229/j.cnki.jdxbgxb.20210797.
Structural parameters optimization of louver fins of air⁃cooled charge air cooler